Agarose gel electrophoresis (basic method)

Background

Agarose gel electrophoresis is the easiest and commonest way of separating and analyzing DNA. The purpose of the gel might be to look at the DNA, to quantify it or to isolate a particular band. The DNA is visualised in the gel by addition of ethidium bromide, which is mutagenic, or less-toxic proprietary dyes such as GelRed, GelGreen, and SYBR Safe. Ethidium bromide and the proprietary dyes bind to DNA and are fluorescent, meaning that they absorb invisible UV light and transmit the energy as visible light.

What percentage gel?

Most agarose gels are made between 0.7% and 2%. A 0.7% gel will show good separation (resolution) of large DNA fragments (5–10 kb) and a 2% gel will show good resolution for small fragments (0.2–1 kb). Some people go as high as 3% for separating very tiny fragments but a vertical polyacrylamide gel is more appropriate in this case. Low percentage gels are very weak and may break when you try to lift them. High percentage gels are often brittle and do not set evenly. I usually make 1% gels.

Which gel tank?

Small 8x10 cm gels (minigels) are very popular and give good photographs. Larger gels are used for applications such as Southern and Northern blotting. The volume of agarose required for a minigel is around 30–50 mL, for a larger gel it may be 250 mL. This method assumes you are making a mini-gel.

How much DNA should I load?

The big question. You may be preparing an analytical gel to just look at your DNA. Alternatively, you may be preparing a preparative gel to separate a DNA fragment before cutting it out of the gel for further treatment. Either way you want to be able to see the DNA bands under UV light in an ethidium-bromide-stained gel. Typically, a band is easily visible if it contains about 20 ng of DNA.

Now consider an example. Suppose you are digesting a plasmid that comprises 3 kb of vector and 2 kb of insert. You are using EcoRI (a common restriction enzyme) and you expect to see three bands: the linearised vector (3 kb), the 5' end of the insert (0.5 kb) and the 3' end of the insert (1.5 kb). In order to see the smallest band (0.5 kb) you want it to contain at least 20 ng of DNA. The smallest band is 1/10th the size of the uncut plasmid. Therefore you need to cut 10x20 ng, that is 200 ng of DNA (0.2µg). Then your three bands will contain 120 ng, 20 ng and 60 ng of DNA respectively. All three bands will be clearly visible on the gel and the biggest band will be six times brighter than the smallest band.

Now imagine cutting the same plasmid with BamHI (another popular restriction enzyme) and that BamHI only cuts the plasmid once, to linearise it. If you digest 200 ng of DNA in this case then the band will contain 200 ng of DNA and will be very bright.

Too much DNA loaded onto a gel is a bad thing. The band appears to run fast (implying that it is smaller than it really is) and in extreme cases can mess up the electrical field for the other bands, making them appear the wrong size also.

Too little DNA is only a problem in that you will not be able to see the smallest bands because they are too faint.

Having said all that, DNA gels are forgiving, and a wide range of DNA loads will give acceptable results. I usually digest and load 2–4 µL of the 50 µL obtained from a kit miniprep. For PCR reactions, it depends on the PCR but in routine applications 10–20 µL should be plenty to see the product on the gel.

Which comb?

This depends on the volume of DNA you are loading and the number of samples. Combs with many tiny teeth may hold 10 µL. This is no good if you want to load 20 µL of restriction digest plus 5 µL of loading buffer. When deciding whether a comb has enough teeth, remember that you need to load at least one marker lane, preferably two.

Making the gel (for a 1% gel, 50 mL volume)

Weigh out 0.5 g of agarose into a 250 mL conical flask. Add 50 mL of 0.5xTBE , swirl to mix.

It is good to use a large container, as long as it fits in the microwave, because the agarose boils over easily.

Microwave for about 1 minute to dissolve the agarose.

The agarose solution can boil over very easily so keep checking it. It is good to stop it after 45 seconds and give it a swirl. It can become superheated and NOT boil until you take it out whereupon it boils out all over you hands. So wear gloves and hold it at arms length. You can use a bunsen burner instead of a microwave - just remember to keep watching it.

Leave it to cool on the bench for 5 minutes down to about 60°C (just too hot to keep holding in bare hands).

If you had to boil it for a long time to dissolve the agarose then you may have lost some water to water vapour. You can weigh the flask before and after heating and add in a little distilled water to make up this lost volume. While the agarose is cooling, prepare the gel tank ready, on a level surface.

Add 1 µL of ethidium bromide (10 mg/mL) and swirl to mix

The reason for allowing the agarose to cool a little before this step is to minimise production of ethidium bromide vapour. Ethidium Bromide is mutagenic and should be handled with extreme caution. Dispose of the contaminated tip into a dedicated ethidium bromide waste container. 10 mg/mL ethidium bromide solution is made up using tablets (to avoid weighing out powder) and is stored at 4°C in the dark with TOXIC labels on it.
 
There are alternatives to using toxic and mutagenic ethidium bromide:

Pour the gel slowly into the tank. Push any bubbles away to the side using a disposable tip. Insert the comb and double check that it is correctly positioned.

The benefit of pouring slowly is that most bubbles stay up in the flask. Rinse out the flask immediately.

Leave to set for at least 30 minutes, preferably 1 hour, with the lid on if possible.

The gel may look set much sooner but running DNA into a gel too soon can give terrible-looking results with smeary diffuse bands.

Pour 0.5x TBE buffer into the gel tank to submerge the gel to 2–5 mm depth. This is the running buffer.

You must use the same buffer at this stage as you used to make the gel. ie. If you used 0.6xTBE in the gel then use 0.6xTBE for the running buffer. Remember to remove the metal gel-formers if your gel tank uses them.

Preparing the samples

Transfer an appropriate amount of each sample to a fresh microfuge tube.

It may be 10 µL of a 50 µL PCR reaction or 5 µL of a 20 µL restriction enzyme digestion. If you are loading the entire 20 µL of a 20 µL PCR reaction or enzyme digestion (as I often do) then there is no need to use fresh tubes, just add the loading buffer into the PCR tubes. Write in your lab-book the physical order of the tubes so you can identify the lanes on the gel photograph.

Add an appropriate amount of loading buffer into each tube and leave the tip in the tube.

Add 0.2 volumes of loading buffer, eg. 2 µL into a 10 µL sample. The tip will be used again to load the gel.

Load the first well with marker.

I store my markers ready-mixed with loading buffer at 4°C. I know to load 2 µL and how much DNA is in each band. See below for more on this.
Avoid using the end wells if possible. For example, If you have 12 samples and 2 markers then you will use 14 lanes in total. If your comb formed 18 wells then you will not be using 4 wells. It is best to not use the outer wells because they are the most likely to run aberrantly.

Continue loading the samples and finish of with a final lane of marker

I load gels from right to left with the gel oriented such that the wells are close to the edge of the bench, and the DNA will migrate away from the edge of the bench. This is because gels are published, by convention, as if the wells were at the top and the DNA had run down the page.

Close the gel tank, switch on the power-source and run the gel at 5 V/cm.

For example, if the electrodes are 10 cm apart then run the gel at 50 V. It is fine to run the gel slower than this but do not run any faster. Above 5 V/cm the agarose may heat up and begin to melt with disastrous effects on your gel's resolution. Some people run the gel slowly at first (eg. 2 V/cm for 10 minutes) to allow the DNA to move into the gel slowly and evenly, and then speed up the gel later. This may give better resolution. It is OK to run gels overnight at very low voltages, eg. 0.25–0.5 V/cm, if you want to go home at 11 O'clock already.

Check that a current is flowing

You can check this on the power-source, the milliamps should be in the same ball-park as the voltage, but the the best way is to look at the electrodes and check that they are evolving gas (ie. bubbles). If not then check the connections, that the power-source is plugged in etc.etc. This has been known to happen if people use water instead of running buffer.

Monitor the progress of the gel by reference to the marker dye.

Stop the gel when the bromophenol blue has run 3/4 the length of the gel.

Switch off and unplug the gel tank and carry the gel (in its holder if possible) to the dark-room to look at on the UV light-box.

Some gel holders are not UV transparent so you have to carefully place the gel onto the glass surface of the light-box. UV is carcinogenic and must not be allowed to shine on naked skin or eyes. So wear face protection, gloves and long sleeves.

Loading buffers

The loading buffer gives colour and density to the sample to make it easy to load into the wells. Also, the dyes are negatively charged in neutral buffers and thus move in the same direction as the DNA during electrophoresis. This allows you to monitor the progress of the gel. The most common dyes are bromophenol blue (Sigma B8026) and xylene cyanol (Sigma X4126). Density is provided by glycerol or sucrose.

Typical recipe

The exact amount of dye is not important
Store at 4°C to avoid mould growing in the sucrose. 10 mL of loading buffer will last for years.

Bromophenol blue migrates at a rate equivalent to 200–400 bp DNA. If you want to see fragments anywhere near this size then use the other dye because the bromophenol blue will obscure the visibility of the small fragments. Xylene cyanol migrates at approximately 4kb equivalence. So do not use this if you want to visualise fragments of 4 kb.

Size markers

There are lots of different kinds of DNA size markers. In the old days the cheapest defined DNA was from bacteriophage so alot of markers are phage DNA cut with restriction enzymes. Many of these are still very popular eg, lambda HindIII, lambda PstI, PhiX174 HaeIII. These give bands with known sizes but the sizes are arbitrary. Choose a marker with good resolution for the fragment size you expect to see in you sample lanes. For example, for tiny PCR products you might choose PhiX174 HaeIII but for 6kb fragments you would choose lambda HindIII. More recently, companies have started producing ladder markers with bands at defined intervals, eg. 0.5, 1, 1.5, 2, 2.5 kb and so on up to 10 kb. If you know the total amount of DNA loaded into a marker lane, and you know the sizes of all the bands, you can calculate the amount of DNA in each band visible on the gel. This can be very useful for quantifying the amount of DNA in your sample bands by comparison with the marker bands. It is good to load two markers lanes, flanking the samples. Lots of companies sell DNA size markers. It pays to shop around for the cheapest. Often the local kitchen-sink biotech company sells excellent markers.

.

TBE

TBE stands for Tris Borate EDTA.

People also use TAE (Tris Acetate EDTA). Make up a 10x stock using cheap reagents. Do not use expensive 'analytical grade' reagents. Cheap Tris base and boric acid can be bought in bulk.

Recipe for 2L of 10xTBE

Dissolve the ingredients in 1.9 L of distilled water. pH to about 8.3 using NaOH and make up to 2 L.

.

No responsibility is assumed by methodbook.net for any injury and/or damage to persons or property as a matter of products liability, negligence or otherwise, or from any use or operation of any methods, products, instructions or ideas contained in the material herein. It is the users responsibility to ensure that all procedures are carried out according to appropriate Health and Safety requirements.